ibaCapture
Version history
Version compatibility
Current version
VersionOperating systemRequirements
v5.5.0Windows 10 (x86/x64)Version 1607 or later
.NET Framework 4.8 (integrated in OS in version 1903 and later)
Windows 11 (x64).NET Framework 4.8 (integrated in OS)
Windows Server 2016 (x64).NET Framework 4.8
Windows Server 2019 (x64).NET Framework 4.8
Windows Server 2022 (x64).NET Framework 4.8 (integrated in OS)
Windows Server 2025 (x64).NET Framework 4.8 (integrated in OS)
HardwareRequirements
LicenseibaCapture v5 license
Wibu CmDongle or CmActLicense
Marx dongle with valid EUP date
VirtualizationCloud virtualization (e.g., AWS, Azure, GCP) is currently not supported.
GigE Vision camerasTested with Windows 10. Support for server operating systems depends on the used SDK.
SoftwareRequirements
.NET FrameworkVersion 4.8 or higher is required.
CodeMeter Runtimev7.10a or higher is required when using a Wibu license
ibaAnalyzer v7.2.0Required for full user management support
ibaPDA v7.2.0Required for synchronized data acquisition
ibaPDA v8.1.0Required if to be used on the same system
ibaVision v3.1.0Required if to be used on the same system
Common Vision Blox Manager v13.01.0004Exact version required for GigE Vision cameras configured as CVB source
Included componentsRemarks
CodeMeter Runtime v8.20a (v8.20.6558.501)v7.10a or higher is required when using a WIBU license.
ibaCapture-ScreenCam filters v1.0.0
ibaCapture player v6.1.3
ibaDongleViewer v2.5.1
ibaManagementStudio Agent v2.1.1
LAV Filters v0.79.2
Previous versions
VersionChangesNotes
v5.5.0Windows 10 (x86/x64), Windows 11 (x64), Windows Server 2016 (x64), Windows Server 2019 (x64), Windows Server 2022 (x64) and Windows Server 2025 (x64)Windows Server 2025 (x64) is supported.
CodeMeter Runtime v8.20a (v8.20.6558.501)
ibaCapture player v6.1.3
ibaManagementStudio Agent v2.1.1
v5.4.0ibaCapture player v6.0.7
v5.3.3CodeMeter Runtime v8.10b (v8.10.6237.502)
ibaCapture player v6.0.5
v5.3.2CodeMeter Runtime v8.10 (v8.10.6221.500)
ibaCapture player v6.0.4
LAV Filters v0.79.2
v5.3.1CodeMeter Runtime v8.00a (v8.0.5974.501)
ibaCapture-ScreenCam filters v1.0.0
ibaCapture player v6.0.0Uses a new versioning that is separate from the ibaCapture product version
ibaDongleViewer v2.5.1
ibaManagementStudio Agent v1.4.0
v5.3.0Windows 10 (x86/x64), Windows 11 (x64), Windows Server 2016 (x64), Windows Server 2019 (x64) and Windows Server 2022 (x64)Windows 8.1 (x86/x64) and Windows Server 2012 R2 (x64) are no longer supported.
v5.2.2CodeMeter Runtime v7.60b (v7.60.5615.502)
ibaManagementStudio Agent v1.3.1
LAV Filters v0.77.1
v5.2.1ibaManagementStudio Agent v1.2.1
CodeMeter Runtime v7.60a (v7.60.5609.501)
v5.2.0Windows 8.1 (x86/x64), Windows 10 (x86/x64), Windows 11 (x64), Windows Server 2012 R2 (x64), Windows Server 2016 (x64), Windows Server 2019 (x64) and Windows Server 2022 (x64)Windows 7 (x86/x64), Windows Server 2008 R2 (x64) and Windows Server 2012 (x64) are no longer supported.
.NET Framework 4.8Required
CodeMeter Runtime v7.60 (v7.60.5598.500)
ibaAnalyzer v7.2.0
ibaPDA v7.2.0
ibaDongleViewer v2.5.0
ibaManagementStudio Agent v1.2.0
v5.1.8CodeMeter Runtime v7.51 (v7.51.5429.500)
v5.1.7.NET Framework 4.8.1Supported
v5.1.5CodeMeter Runtime v7.40b (v7.40.5001.502)
v5.1.3CodeMeter Runtime v7.21a (v7.21.4611.501)
v5.0.3CodeMeter Runtime v7.10a (v7.10.4196.501)Required when using a Wibu license
v5.0.2CodeMeter Runtime v7.10 (v7.10.4188.500)
v5.0.0LicenseibaCapture v5 license
Wibu CmDongle or CmActLicense (CodeMeter Runtime v7.00 or higher)
Marx dongle with valid EUP date
v4.5.3ibaDongleViewer v1.9.6
v4.5.1ibaDongleViewer v1.9.4
v4.4.1ibaDongleViewer v1.9.3
v4.4.0ibaDongleViewer v1.9.2
Common Vision Blox Manager v13.01.0004
LAV Filters v0.74.1
v4.3.3LAV Filters v0.73.1
v4.3.2.NET Framework 4.8Supported
v4.3.1ibaDongleViewer v1.8.2
Common Vision Blox Manager v13.01.0002
v4.3.0ibaDongleViewer v1.8.0
Common Vision Blox Manager v13.00.0006
v4.2.1ibaDongleViewer v1.7.1
v4.2.0ibaDongleViewer v1.7.0
v4.1.2.NET Framework 4.7.1Supported
ibaDongleViewer v1.6.13
v4.1.1ibaDongleViewer v1.6.12
v4.0.5ibaDongleViewer v1.6.11
v4.0.4ibaDongleViewer v1.6.8
v4.0.1ibaDongleViewer v1.6.7
v4.0.0.NET Framework 4.5.2Required
ibaPDA v6.36.6Required for synchronized data acquisition
ibaDongleViewer v1.6.5
v3.7.2ibaPDA v6.34.5Required for using AXIS control boards
v3.7.0.NET Framework 4.6Supported
v3.6.0ibaPDA v6.31.0Required for PTZ control
v3.4.0.NET Framework 4.0Required
ibaAnalyzer v6.0.0Required for full user management support
ibaPDA v6.29.0Required for full user management support

Version 5.5.0 - 2025-06-04
Required EUP date - 2025-06-04

New features (N)

  1. ibaCapture supports video format changes when replaying video. #11149
  2. ibaCapture now has the capability to require 2 person authentication for accessing a camera. #27712

Improvements (I)

  1. Manager: Settings now have an option to always display the Manager window on top. #13822
  2. Manager: Settings now have an option to select what screen mode should be used when starting the Manager application. #16678
  3. Manager: Image adjustment slider in the corner of the camera view can now be disabled in the properties settings. #18088
  4. Manager: The server status application now has a button to start the Manager. #18748
  5. Manager: Lines can now be snapped to angles when drawing a polygon for a privacy mask/overlay image. #22382
  6. Manager: When the login fails, the camera replay now shows more informative error messages. #30643
  7. Manager: The 'default' profile can now be selected for transcoding to ensure a close match to the original video quality when exporting. #17825
  8. Manager: When adding a new camera, the wizard hides steps that are not relevant for it. #31517
  9. Manager: When configuring the storage path of a camera, it is now possible to add a new folder or refresh the list with existing folders. #31519
  10. Server: The startup of a livestream could hang when another PC with a bad connection was blocking the server. #31126
  11. Server: Improve the video delay of ONVIF cameras when using a TCP stream. #30982
  12. Server: Faster startup of ONVIF cameras. #30982
  13. Server: If the validation of a GigE or ScreenCam camera fails, the camera name is now included in the log message. #31659

Bug fixes (B)

  1. Manager: Stability improvement when adding or removing a camera to the configuration. #30295
  2. Manager: Stability and error feedback improvements when exporting a video. #3044
  3. Manager: Changes to export settings would not be saved correctly under certain circumstances. #31232
  4. Manager: Fixed a rare null reference exception crash when the connection to a server hangs. #31233
  5. Manager: When the RTSP server was disabled, the ibaCapture server always incorrectly detected changes to the RTSP config when applying it. #31234
  6. Manager: Fixed an error where the storage path could be lost after disabling and re-enabeling a camera. #29392
  7. Manager: The validation of an alternative stream would fail for an RTSP camera source. #30628
  8. Manager: When adding an ibaVision camera, the back button could cause a crash. #31516
  9. Manager: Clearing the storage path in the camera settings, would make it impossible to reset it back to the default value. #31518
  10. Manager: If the layout was saved when a camera is viewed in maximized mode, the layout could get mixed up. #30793
  11. Manager: Importing user management data from ibaCapture <=5.2 would cause an error. #31660
  12. Manager: A bug could cause some cameras to not be displayed in the export selection dialog. #31881
  13. Manager: A connection loss could sometimes cause a crash when exporting video to a network location. #31834
  14. Player: When exporting with a timestamp overlay, the black background behind the text would sometimes be too short. #29721
  15. Including the WIBU JSON file in the support file would fail for systems without any WIBU containers and an exception would be logged. #31719

 

Version 5.4.0 - 2024-11-06
Required EUP date - 2024-11-06

New features (N)

  1. Manager: In the camera configuration a new "Storage overview" node was added where the used storage for each camera is listed. #22381
  2. Manager: Added ability to set the display style to "Normal", "Enlarged", "Fullscreen" or "FullAllScreens" on startup of the application with the command line switch "/displaystyle:". #26439
  3. Manager: The cameras now have customizable tags, that can be used to filter cameras in the server overview. #26837
  4. Manager: When the configuration or layout changes, a backup of the old version is saved. #22381
  5. Encoder: The automated startup can now be delayed. #28765
  6. It is now possible to set an alias as the server name. #28409
  7. ibaManagementStudio: Support ibaCapture GigE Vision Encoder diagnostics queries. #28289

Improvements (I)

  1. Manager: In the camera storage settings the visual representation of the storage now also shows the space occupied by the other cameras. #19864
  2. Manager: Display an error message when protecting video and there is no allocated protected disk space. #16525
  3. Manager: The user is now asked to restart the application after the language was changed. #24619
  4. Manager: It is now possible to set a default value for the storage size and protected size of new cameras. #22380
  5. Manager: Removed redundant start/stop recording buttons from the configuration. #14013
  6. Manager: Improve the readability of the client connections by removing the port numbers from the address. #28766
  7. Manager: The configuration and layout changes are now automatically saved every 5 minutes. #21772
  8. Manager: Generated support files now always include up to date configuration files of the ibaCapture Manager. #21772
  9. Manager: It is now possible to select newly added servers when generating the support files. #21772
  10. Server: Detect changes in the WIBU licenses while running and apply them. #27921
  11. Installer: #28353
    1. Service user pages are also visible when updating.
    2. Third-party installers are available in the Installers folder of the installation folder.
    3. By default a shortcut to the ibaCapture Manager is created on the desktop.
    4. Upon first installation start menu shortcuts to folders could be invalid. #29080

Bug fixes (B)

  1. Manager: In the camera configuration, other controls no longer lose focus when hovering over the visual representation of the storage. #27755
  2. Manager: In the camera info, the status, diagnostics and preview tabs do not break when the window is small. #8783
  3. Manager: When configuring the storage path for a camera, and several paths have been typed, all variants were shown as directories in the drop-down directory listing. #13401
  4. Camera view: When the timeline was collapsed, the player count and storage colors were switched for selected and unselected players. #29229
  5. Server: Reject manually changed configurations with the camera storage on a network path. #26558

 

Version 5.3.3 - 2024-08-07
Required EUP date - 2024-01-24

Bug fixes (B)

  1. Installer: Updating the Codemeter Runtime on 64-bit systems would cause licensing errors in iba 32-bit applications. #28892
  2. Player: Exporting video from a file would fail. #28473
  3. Manager: It was not possible to add or remove live view priorities. #28548

 

Version 5.3.2 - 2024-06-20
Required EUP date - 2024-01-24

Bug fixes (B)

  1. Manager: Format for MPEG4 sources was incorrectly shown as '??' in camera status information in server configuration. #27899
  2. Manager: Non-camera settings would not be loaded correctly when importing a configuration. #23682
  3. Manager: Fix issue where it was not possible to abort the dragging of a camera onto the view. #28284
  4. Server: Video segment changes could be missing from the query results for the ibaCapture Manager after storage configuration changes. #27949
  5. Server: ibaCapture was unable to consume certain RTSP streams. #28369
  6. Server: Non-ASCII characters in camera names would produce various errors in ibaPDA >= v8.3. This has been fixed with ibaPDA v8.7.3. As a workaroud for older ibaPDA versions, camera names in those versions will now only display ASCII characters. #28370

 

Version 5.3.1 - 2024-04-22
Required EUP date - 2024-01-24

Bug fixes (B)

  1. Player: A debug message box would pop up when using the ActiveX ibaCapture Player component (used in ibaAnalyzer) (bug introduced in v5.3.0). #27126
  2. Player: Video sources using MPEG4 encoding could not be displayed in the ibaCapture Player(bug introduced in v5.3.0). #27844
  3. Server: The support file would not include the ibaCapture GigE Vision log files (bug introduced in v5.3.0). #26986
  4. Server: Fixed a very rare crash when closing a connection with an ONVIF or RTSP camera. #27520
  5. Server: ibaPDA v8.3 or newer would not display non-ASCII characters(like umlauts) in camera and server names correctly. #27518
  6. Encoder: Encoder would produce an excessive amount of keyframes, which reduced performance and compression rate (bug introduced in v5.3.0). #27307
  7. Video export with transcoding would sometimes fail and hang when using the Intel encoder. #27476

 

Version 5.3.0 - 2024-01-24
Required EUP date - 2024-01-24

The Matrox Imaging Library SDK is no longer supported for GigE Vision camera sources.

New features (N)

  1. Video can now be transcoded to a different format & resolution when exporting. #8744
  2. Video from cameras with active overlay image can now be exported. #8744
  3. A timestamp overlay can now be added to exported video, if transcoding is enabled. #10942

Improvements (I)

  1. Server: A menu item to restart the ibaCapture Server was added to the tray icon context menu of the status application. #24358
  2. Encoder: When using the eBUS SDK, the encoder will now use camera hardware timestamps(if possible) for better accuracy. #24623
  3. Encoder: A key frame will now be forced to be created after multiple missing frames. #24909
  4. Player: Stored video from ibaCapture-ScreenCam, ibaVision and GigE Vision sources can now always be replayed, even if the device is not reachable. #26128
  5. Manager: Improved the shown camera status of new and disabled cameras in the configuration view. #26122

Bug fixes (B)

  1. Camera view: Opening the video export form could result in an application hang on rare occasions. #26726
  2. Server: An exception while processing an incoming active TCP live stream request would close the port for subsequent requests. #26066
  3. Manager: When ForceSelectAll mode was enabled, the AXIS control board Next/Previous buttons did not disable it correctly and got stuck on the first camera. #23427
  4. Manager: The "Show live" function of the AXIS control board did not work correctly. #26456
  5. Manager: When AXIS control board was used in ibaCapture Manager and ibaPDA at the same time, using applications would sometimes hang on exit. #26489
  6. Support tool: Support files included incorrect Player log files from old ibaCapture installs. #25236
  7. ibaCapture was unable to consume certain RTSP streams due to an incorrect URI (bug introduced in v5.2.0). #19534
  8. Video export would sometimes produce corrupted video files when exporting video with multiple gaps. #24907

 

Version 5.2.2 - 2023-07-18
Required EUP date - 2023-04-04

Improvements (I)

  1. Installer: CodeMeter Runtime upgrades can now be skipped during install. #24380

Bug fixes (B)

  1. Player: The replay of certain exported video files would loop during video gaps (even while paused). #24907
  2. Player: The ibaCapture Player would still default to ffdshow decoding instead of LAV Filters decoding. #24880
  3. Server: A bug when deleting video older than the configured limits could result in future video loss (bug introduced in v5.1.6). #24816
  4. Encoder: An uncaught InvalidOperationException could be thrown on the log tab.
  5. The ibaCapture installer would unnecessarily add the Matrox GigE service (when installed) as a service dependency for the ibaCapture Server.
  6. Remote support file generation could fail because of missing files, file transfer size limits and timeouts. #24997

 

Version 5.2.1 - 2023-05-25
Required EUP date - 2023-04-04

ibaAnalyzer replay of exported ibaCapture-CAM v1/v2 video files embedded in DAT files is not supported on Windows 11 and Windows Server 2022.

Improvements (I)

  1. Installer: CodeMeter Runtime is now only installed if the ibaCapture Server component is selected. #24466

Bug fixes (B)

  1. Player: Resolution changes while decoding resulted in errors when copying images from embedded players (used in ibaVision and the ibaPDA service). #24350
  2. Manager: Camera discovery for ONVIF devices using the ONVIF profile S did not work correctly. #24388
  3. Manager: The ibaCapture Manager would sometimes encounter unhandled exceptions when updating a server status. #20120
  4. Encoder: Setting the NVIDIA encoder width or height to an odd value would produce a blank video output. Odd values are no longer allowed and will fail the validation. #24413
  5. Encoder: When running with the eBUS SDK, the network adapter field would show a string consisting of both the MAC and the IP address. The IP address was removed from this field. #24530
  6. ibaCapture failed to connect to certain ONVIF sources due to unsupported headers in the SOAP responses. #24442
  7. PTZ support is improved for certain ONVIF sources. #24489
  8. Installer did not work correctly on Windows 11 and would produce error messages. #24558

 

Version 5.2.0 - 2023-04-04
Required EUP date - 2023-04-04

Server configuration files created with v5.2 are not backwards compatible with older versions. This may cause issues when downgrading to an older version.
Windows 7 (x86/x64), Windows Server 2008 R2 (x64) and Windows Server 2012 (x64) are no longer supported.

New features (N)

  1. Server: ibaCapture Server diagnostics are shown in the ibaManagementStudio web client. (This requires ibaManagementStudio Server and Agent v1.1.0 or higher.) #20806
  2. Installer: The ibaManagementStudio Agent can now be installed from the ibaCapture installer. #20788
  3. Manager: Cameras can be hidden from ibaPDA via signal assignment. #19479

Improvements (I)

  1. Player: ffdshow is no longer installed by the ibaCapture installer. LAV Filters remains the default decoder. #20108
  2. Encoder: Upgraded Intel Quick Sync encoding from the Intel Media SDK to the OneVPL SDK 2022.1. #21135
    Intel Quick Sync encoding is no longer supported on 32-bit systems and/or on systems running an OS older than Windows 10.
  3. ibaCapture-CAM v1/v2 servers are no longer supported: #20241
    1. The ibaCapture Manager is no longer able to connect to ibaCapture-CAM v1/v2 servers.
    2. The ibaCapture Server can still import ibaCapture-CAM v1/v2 server configurations when upgrading.
    3. ibaAnalyzer (32-bit) is still able to replay exported ibaCapture-CAM v1/v2 video files embedded in DAT files.
  4. Credentials stored in the configuration files are now AES-256 encrypted. #20921
  5. Camera view: User management interaction permissions through ibaPDA are now supported. All controls in the camera view can be disabled. #21426
  6. Camera view: Increased the size of the camera view toolbar/icons in ibaPDA. Some icons were changed. #21530
  7. Camera view: When switching to next/previous camera through the AXIS control board they are now switched in a gridlike/left->right & top->bottom order. #22817
  8. Camera view: The log file now contains the found AXIS control board devices on the system. #8665

Bug fixes (B)

  1. Server: The ibaCapture Server could crash if more than 64 cameras were configured. #19479
  2. Server: The generation of remote server support files was broken (bug introduced in ibaCapture v5.1.8). #23212
  3. Manager: The AXIS control board command for toggling between live/recorded video of selected cameras did not work. #22427
  4. Manager: Depending on the ibaVision connection status and configuration, certain actions while configuring an ibaVision source in ibaCapture Manager could result in a corrupted configuration for this source.
  5. Manager: Server overview list would jump position when views started/stopped playing. #23500
  6. Manager: The camera search in the server overview was case sensitive when only a single character was entered. #23473
  7. Camera view: Camera nodes could show a busy status indefinitely in the protect/lock form. #22745
  8. Player: Offline ibaVision programs could crash due to an uncaught exception in the ibaCapture Player thrown on ibaCapture Server disconnects.
  9. Encoder: Some Baumer cameras could not be added to ibaCapture using the eBUS SDK. #22797
  10. Certain MARX dongle fields showed incorrect values in the license overview in the ibaCapture Manager (bug introduced in ibaCapture v5.0.0). This fix only applies for ibaCapture Servers v5.0.0 and higher. #23805 #23807

 

Version 5.1.8 - 2022-10-18
Required EUP date - 2020-11-30

Bug fixes (B)

  1. Camera view: The video segment information shown on the timeline could be incomplete. #22012
  2. Camera view: Added support for Rev2 versions of the AXIS KeyPad and AXIS JogDial devices.
  3. Manager: Specific actions while adding a new camera could lead to an error when attempting to apply the server configuration. #22020
  4. Manager: The ibaCapture Manager could crash while configuring AXIS cameras due to unhandled exceptions.
  5. Manager/Encoder: Installing the Pleora eBUS Runtime while the application is running could result in undefined behavior. #22023
  6. Player: The handling of resolution changes reported by the LAV video decoder could lead to a crash of ibaPDA. #22200
  7. Server: Failed initializations of clients for RTSP sources could lead to port exhaustion. #22530
  8. Installer: The installer would hang while enumerating the locking processes on Windows 7 (perhaps on other operating systems as well). #22346

 

Version 5.1.7 - 2022-08-24
Required EUP date - 2020-11-30

New features (N)

  1. ibaCapture supports .NET Framework 4.8.1.

 

Version 5.1.6 - 2022-06-22
Required EUP date - 2020-11-30

Improvements (I)

  1. Camera view: Allow millisecond precision in the scenario player's time span configuration. #19619
  2. Manager: The camera configuration wizard now skips non-applicable categories during camera setup. #8784
  3. Manager: When configuring RTSP sources, the GOP size measurement will fall back to TCP if RTP over UDP fails. #13433
  4. ibaCapture supports the AXIS bitrate control modes MBR and ABR. #21594

Bug fixes (B)

  1. Server: Different deletion thresholds for regular and protected/locked video could result in inconsistent server behavior (bug introduced in ibaCapture v5.1.0).
  2. Installer: When listing blocking processes, the use of managed dependencies (e.g., View.ibaCapture.dll) would be overlooked. #21298
  3. Network communication between the ibaCapture Manager and Server could be severely impacted when video storages contained a large number of video segments. #21156
  4. Consuming an RTSP stream over UDP could fail due to ibaCapture using different IP addressess for the RTSP and RTP/RTCP communication. #21463
  5. Manager: When adding new ScreenCams, IPs entered in the 'Host Address' box would change to the host name #20796

 

Version 5.1.5 - 2022-05-03
Required EUP date - 2020-11-30

Improvements (I)

  1. Manager: New option in general settings allows to limit the ibaCapture Manager to a single instance. #20147

Bug fixes (B)

  1. Player: Exporting video with gaps could result in an application crash due to an access violation (bug introduced in ibaCapture v5.0.0). #19825
  2. Player: Disposing a replay stream could result in an uncaught NullReferenceException. #20020
  3. Player: Improved the loading of slave camera images for offline ibaVision programs. #20123
  4. Manager: Applying or loading a configuration could result in uncaught exceptions. #20052
  5. Manager: Failure to establish a connection to the server could result in an exceptions. #20615
  6. Manager: Setting the frame rate for alternative streams was not possible when using the French localization. #20948
  7. Camera view: An unhandled exception could be thrown when the scenario player received NaN from an ibaPDA channel. #19611
  8. Camera view: An unhandled exception could be thrown when switching between images in the scenario player. #20403
  9. Camera view: Lazily loaded camera channels in the scenario player possibly resulted in undesired side-effects, such as time drift. #20078
  10. Aggregation packets from an HEVC RTSP stream would be parsed incorrectly.
  11. Parsing the stream description of an RTSP stream could result in incorrect property values.
  12. ibaCapture was unable to consume certain RTSP streams due to the usage of an incorrect URI. #19534
  13. On certain systems, ibaAnalyzer was unable to load embedded Cossilys video files due to missing dependencies.

 

Version 5.1.4 - 2021-08-12
Required EUP date - 2020-11-30

Improvements (I)

  1. Manager: When retrieving camera settings from an RTSP stream, ibaCapture Manager will now display the number of received frames. #18206
  2. Manager: Camera names in the server tree view can now be searched/filtered by the user. #19151
  3. Support tool: Marx dongle VWR files generated by the support tool will now have the dongle serial number in the filename. #19345

Bug fixes (B)

  1. Manager: Improved the shown license serial string in the license overview. #20669
  2. Server: A troublesome incoming live stream request could result in other live streams requests temporarily being refused via active TCP. #19329
  3. ibaCapture was not able to correctly handle RTSP streams that did not provide a stream description. #18015
  4. ibaCapture could crash due to missing CRT dependencies (bug introduced in ibaCapture v5.1.3). #19266
  5. ibaCapture was unable to properly set up a connection to an h.265 RTSP stream.

 

Version 5.1.3 - 2021-07-07
Required EUP date - 2020-11-30

Bug fixes (B)

  1. Manager: The ibaCapture Manager would crash when saving a project configuration that had no local user groups configured. #19084
  2. Server: Video protection failed for cameras with huge storage sizes. #19008
  3. Server: Network problems could lead to the recording being stopped indefinitely for ibaCapture-ScreenCam and ibaVision sources. #19193
  4. ibaCapture was unable to set up streams with ONVIF cameras which support profile T (bug introduced in ibaCapture v5.0.0). #18955
  5. ibaCapture detected only 1 source for certain AXIS cameras with multiple sources (bug introduced in ibaCapture v5.1.2). #18985

 

Version 5.1.2 - 2021-05-11
Required EUP date - 2020-11-30

Improvements (I)

  1. Server: Dongle events in the server logs include the dongle ID. #18484
  2. Defined view areas for AXIS cameras were not exposed in the ibaCapture settings. #18576
  3. The ibaCapture support file includes a vwr-file if there is a Marx dongle present. #18278
  4. The ibaCapture support file includes a ZIP-file containing local Wibu license information. #18279

Bug fixes (B)

  1. Player: Attempting to export h.265-encoded video from embedded video files failed due to an internal infinite loop. #18167
  2. Player: Creation of the DirectShow graph possibly failed when performed in a Session 0 process (bug introduced in ibaCapture v5.1.0). #18641
  3. Player: Players using a Direct3D feature level lower than 11.1 could throw an unhandled NullReferenceException when no video was available. #18691
  4. Player: Attempting to login after the player was disposed (e.g., after the activation of rule in the scenario player) resulted in unhandled exceptions.
  5. Player: A fallback to GDI rendering (in case Direct3D is not supported) was only available in remote sessions. #18732
  6. Camera view: Certain camera controls in the ribbon (ibaCapture Manager) or toolbar (ibaPDA client) were disabled if live licenses were exhausted. #18441
  7. Manager: Upon appending the AXIS URL to the camera address in an RTSP configuration, minus signs (-) would be removed from the camera address. #18697
  8. Server: On rare occasions, an ibaVision or ibaCapture-ScreenCam source would be restarted unintentionally after stopping the recording. #15041
  9. Server: In rare cases, the initialization of RTSP or ONVIF sources led to NullReferenceExceptions. #18672
  10. ibaCapture would report incorrect GOP sizes and frame rates for certain RTSP streams. #18191
  11. ibaCapture was unable to consume multiple RTSP streams on the same local port even when routed via different NICs. #18521

 

Version 5.1.1 - 2021-01-26
Required EUP date - 2020-11-30

Improvements (I)

  1. Server: ibaCapture did not support capturing multicasted RTSP streams. #17893

Bug fixes (B)

  1. Camera view: The initialization of the camera view could lead to an unhandled exception at startup. #18052
  2. Player: Image adjustment sliders would not show/hide correctly. #18056
  3. Player: Certain systems with an older OS could no longer create a video renderer after the Direct3D upgrade in v5.1.0. #18014
  4. Player: On certain systems loading the player would result in an exception because one of its dependencies could not be found (bug introduced in ibaCapture v5.1.0). #18144
  5. Server: Resetting the admin password via a Wibu license didn't work. #17986
  6. Server: Live stream sessions with fixed ports could be shut down prematurely eventually leading to memory allocation issues. #18140
  7. Backwards compatibility with ibaVision v2.0.0 and older was broken (bug introduced in ibaCapture v5.1.0). #18045

 

Version 5.1.0 - 2020-11-30
Required EUP date - 2020-11-30

New features (N)

  1. Manager: The server and user management configuration can be saved as and loaded from ibaCapture project ZIP-files. #17185
  2. Encoder: h.265 encoding is supported. #16672
  3. Support for h.265 video streams from ibaVision (requires ibaVision v2.1.0 or higher). #16673

Improvements (I)

  1. Player: Improved performance by upgrading from Direct3D 9 to Direct3D 11.
  2. Player: The player area is used more flexibly by considering the aspect ratio of the current zoom rectangle instead of the original video aspect ratio. #10522
  3. Camera view: An option to automatically zoom out after a period of inactivity was added to the settings. #17100
  4. Manager: When loading a new overlay image, the user will be asked if he wants to clear the existing overlay or not. #16861
  5. Server: Different deletion times can be set for regular and protected/locked video in the storage configuration. #10419

Bug fixes (B)

  1. Camera view: Disposed player separators regularly remained visible after size changes, etc. #17377
  2. Manager: In certain cases the defined video overlay would disappear when opening the editor in the configuration. #17488 #17637
  3. Manager: An InvalidOperationException could be thrown while painting the ribbon when switching back automatically to live view after a period of inactivity. #17654
  4. Manager: Loading a user management configuration from a file would result in a duplicate entry in the user tree in certain cases. #17759

 

Version 5.0.2 - 2020-09-17
Required EUP date - 2020-07-08

Bug fixes (B)

  1. Player: The player could crash due to an incomplete handling of a resolution change by the decoder.
  2. Player: Live players with the option 'Key frames only' activated would not display video (bug introduced in v5.0.0). #17375
  3. Several bug fixes from ibaCapture v4.5.2 were not ported to v5.0.0.

 

Version 5.0.1 - 2020-08-11
Required EUP date - 2020-07-08

Improvements (I)

  1. Manager, Server: The maximum frame rate of Axis cameras has been increased from 120 fps to 500 fps. #17002
  2. Manager: The video codec is added to the stream information in the camera status. #16700

Bug fixes (B)

  1. Camera view: Replay speed couldn't be changed anymore via the toolbar (bug introduced in v5.0.0). #17099
  2. Camera view: Triggered replay rules in the scenario paused the player instead of applying the desired speed. #17142
  3. Server: in certain cases, ibaCapture did not free livestream licenses. #17167

 

Version 5.0.0 - 2020-07-08
Required EUP date - 2020-07-08

Wibu CodeMeter license or Marx dongle with valid EUP date is required.

New features (N)

  1. Manager, Server, Player: Support for h.265 video streams. #11917
  2. Manager, Server, Player: Support for video image overlay. #9258
  3. Manager, Server: Support ibaCapture-ScreenCam password (ibaCapture-ScreenCam v5.0.0 and higher is required). #8737
  4. Manager: Both entire camera layouts and single cameras can be printed. #10588
  5. Manager: All cameras from an ibaCapture server can be opened at once. #13513
  6. Manager: Language can be changed dynamically.
  7. Manager, Server, Player: Chinese language support.
  8. Server: Axis cameras can now be connected via https. #15527

Improvements (I)

  1. Manager: If connection to ibaCapture-ScreenCam via host name fails then ask to connect via IP address. #15745
  2. Manager: Option to switch all players to live mode when loading a layout. #15249
  3. Manager: Improved useability when discovering ibaCapture-ScreenCam cameras. #16642
  4. Player: Extended player debug information. #15741
  5. ScenarioPlayer: Use replay speed from ibaPDA signal. #16379
  6. Player: New user right to change password. #15585
  7. Server: RTSP server supports alternative live streams. #14796
  8. Camera view: Protected and locked parts are shown in collapsed time line. #16522

Bug fixes (B)

  1. Manager: fixed possible exception when opening Encoder Configuration. #16431
  2. Server: Problems with DNS lookup in RTCP streams could crash the complete server. #16905
  3. Support tool: If collecting system information failed then no support file was generated.

 

Version 4.5.4 - 2020-05-04
Required EUP date - 2019-07-03

Improvements (I)

  1. Camera view: The root node in the properties has the correct name now. #16207
  2. Manager: Client connections grid in the service status can be exported to a text file.

Bug fixes (B)

  1. Server: Reducing storage for cameras didn't work correctly. Files could be left and video could be missing. Protected/locked files could be unnecessarily deleted. #16471
  2. Player: Player could crash when the resolution of the decoded video is different from the resolution of the encoded video. This only happened when generating image triggers in ibaPDA. #16426
  3. Camera view: Player automatically starts replay when jumping into "no video available". #16516
  4. Camera view: Idle time calculation was not always correct. #16503
  5. Camera view: Signal references from the scenario player rules were not removed when the camera view was removed. #16395
  6. Manager: After initializing a new camera, continuous recording start time is not updated. #16247
  7. Manager: Video segments were not sorted correctly when sorting by start time or end time column in the video segments grid. #16012

 

Version 4.5.3 - 2020-03-09
Required EUP date - 2019-07-03

Improvements (I)

  1. Server: Reduced unnecessary logging. #15684
  2. Manager: Default bit rates for the GigE video encoder have been increased. #15685
  3. Manager: Camera storage information is shown even when the camera isn't recording. #16005
  4. Camera view: there is an option to automatically return to Live mode after a configurable time of inactivity. #15756
  5. Camera view: Message boxes are drawn in the style of the host program. #15935
  6. Server: Old video can be deleted after 1 day. Before this could only be done after 7 days. #16004

Bug fixes (B)

  1. Camera view: replay speed zero wasn't allowed in the scenario player. #15642
  2. Camera view: players with different time stamps and/or different speeds are again possible in the scenario player. #15532
  3. Camera view: auto focus didn't work when PTZ was controlled via the mouse on Axis cameras. #16236
  4. Manager: ONVIF profiles that were larger than 64 kB couldn't be read from an ONVIF device. #15906
  5. Manager: Admin passwords are limited to 15 characters. This limitation is now checked. #15997
  6. Manager: User accounts with empty names could be created. #15998

 

Version 4.5.2 - 2019-10-23
Required EUP date - 2019-07-03

Improvements (I)

  1. Scenario player: The default zoom setting from the server is used. #15308
  2. Scenario player: Disabled zooming with middle mouse button when in scenario mode. #15430

Bug fixes (B)

  1. Camera view: camera names were not updated. #11710
  2. RTSP server: SETUP response contains wrong ports. #15401
  3. Camera view: solved crash when time stamp was cleared. #15418
  4. Camera view: the timeline was always hidden when creating a new view. #15429
  5. Player: for AXIS cameras, a green line would appear when using some resolutions in combination with NV12 or YV12 color space. #15386

 

Version 4.5.1 - 2019-09-04
Required EUP date - 2019-07-03

Improvements (I)

  1. Manager: [F11] can be used to cycle through the previously opened camera view layouts. #14854
  2. Player: disabled multithreading for the LAV video decoder to reduce delay and memory consumption.
  3. RTSP sources: if present, the authorization header of outgoing DESCRIBE requests is logged. #14968

Bug fixes (B)

  1. Camera view: using a replay trigger command with an empty offset signal in the scenario player would result in a crash of the ibaPDA client. #15202
  2. Camera view: the form displaying command settings of scenario player rules could be initialized with an incorrect replay speed value. #15203
  3. Player: when exporting multiple videos at once, the export would always fail for the first player due to a bug in replay synchronization. #15040
  4. Server: the ibaCapture Server could become congested with live stream requests. #15177

 

Version 4.5.0 - 2019-07-03
Required EUP date - 2019-07-03

New features (N)

  1. GigE Vision cameras can be configured as multicast slaves (using Pleora's eBUS SDK). #14242
  2. ibaCapture servers can be set up as RTSP server allowing clients to access live and/or recorded video content via RTSP streams. #9164

Improvements (I)

  1. Camera view: [F6] can be used to force all players to live mode or pause them. #14850

Bug fixes (B)

  1. Camera view: in certain cases, players could not be forced into live mode. #14659
  2. Player: streams with rectangular pixel aspect ratios (e.g., PAL, NTSC) would be distorted when decoded with the LAV video decoder. #14872
  3. Player: the displayed player status would sometimes not match with the actual status. As a result of this, users could experience difficulties when, for example, starting or pausing the players. #14874
  4. Encoder: UDP ports would not be freed after discovery (while in eBUS mode). #14655
  5. Server: ibaCapture Servers could continuesly try reconnecting to RTSP sources while the camera was disabled or even removed. #14651
  6. Server: the SNMP values for the license and recording state could be incorrect. #14801
  7. RTSP sources: the URIs of RTSP sources would be unescaped before sending out the requests.
  8. RTSP sources: when using the 'OPTIONS'-request as keepalive, the session ID would not be included.
  9. For certain cameras (e.g., Hikvision cameras) RTSP authentication would fail. #14599
  10. Windows Media Player would no longer play exported ibaCapture-ScreenCam videos after installing ibaCapture v4.3.3. #14603

 

Version 4.4.1 - 2019-05-08
Required EUP date - 2019-03-20

Improvements (I)

  1. Manager: to prevent unintentional server configuration changes, the server configuration will be loaded in read-only mode if it contains an unknown camera type.
  2. Video export information has been added to the user activity log files. #14110

Bug fixes (B)

  1. Server: after changing the order of cameras in the ibaCapture Manager, ibaPDA commands would be applied to the wrong cameras. #14364
  2. Player: under certain circumstances, players would start running at a high speed while they should be paused. #14196
  3. Player: video export of small time ranges could result in corrupt MP4 files.

 

Version 4.4.0 - 2019-03-20
Required EUP date - 2019-03-20

New features (N)

  1. Player: saturation and hue can be changed. #13511
  2. Player: the ibaCapture Player allows video rotations by 90, 180 and 270 degrees. #13442
  3. Player: main stream access can be restricted through user management. In case a user is not allowed to request main stream access, the ibaCapture Player will automatically try to request an alternative stream (if available). #12126
  4. Manager: remote server configuration can be disabled on the 'General settings' node in the server configuration. #12127
  5. Manager: user management configurations can be imported and exported. #9042
  6. Manager: the order of the cameras can be changed using drag and drop on the treelist of the server configuration. #13463
  7. Default ibaCapture Player settings (such as zoom factor, rotation, etc.) can be set per camera in the server configuration. #8642
  8. A second button has been added to the ibaCapture Player which allows local ibaCapture users to change their password. #12986

Improvements (I)

  1. Player: in addition to JPEG, images can now be exported as PNG, BMP or TIFF. #12247
  2. Encoder: upgraded CVB dependencies to v13.01.0004.
  3. Support file generation has been improved: #10023
    1. ibaCapture Server information can be added remotely. This requires the ibaCapture Server version to be v4.4.0 or higher.
    2. Multi-volume ZIP-files are supported.
  4. Certain actions are logged in separate access log files using either a default format or the CSV format. The retention period (which can be changed) for these files is 30 days. It is also possible to set an alternative (UNC) storage path for these files. #12987
  5. The order of ibaCapture cameras in ibaPDA can be changed by assigning them to signal IDs on the 'ibaPDA communication'-node in the server configuration. #8641

Bug fixes (B)

  1. Manager: new domain users would be added with an incorrect domain name. #14326
  2. Player: ibaCapture Players behaved incorrectly when displaying video backwards while using the LAV video decoder. #14100
  3. Server: under certain circumstances it was possible to apply multiple configurations concurrently which could result in undefined behavior of the ibaCapture Server. #13995
  4. Server: fragmented RTSP streams could result in corrupted video content. #14294
  5. Encoder: NVIDIA-encoded streams were not fully compatible with image triggers used in ibaPDA. #14024

 

Version 4.3.3 - 2018-11-21
Required EUP date - 2018-07-12

Improvements (I)

  1. Camera view: signal values can be used as offset for trigger rules in the scenario player. #13519
  2. Player: the delay between pressing the [ALT] key and the activation of panning has been reduced. #13744
  3. Player: ffdshow decoder has been replaced by the LAV video decoder. #13522
  4. Player: certain log messages are temporarily suppressed during availability tests of Direct3D. #13326

Bug fixes (B)

  1. Manager: domain users could be added to local user groups, but the changes would not persist. #13727
  2. Manager: the ibaCapture Manager was unable to authenticate against RTSP sources which do not support 'Basic' as authentication scheme. #13773
  3. Server: the ibaCapture Server sometimes reported wrongly that a ScreenCam instance was already in use when applying a configuration. #13709
  4. A bug in the parser of the h.264 sequence parameter set prevented the start of certain RTSP cameras. #13774

 

Version 4.3.2 - 2018-10-17
Required EUP date - 2018-07-12

New features (N)

  1. ibaCapture supports .NET Framework 4.8.

Improvements (I)

  1. Manager: user-friendliness of the storage path control has been increased. #13410
  2. Encoder: previously, searching for GigE cameras in the ibaCapture Manager simply returned the list of cameras already found by the ibaCapture Encoder. From now on, this will also start a new discovery run in the ibaCapture Encoder. #13407
  3. Encoder: administrative privileges are only requested when enabling/disabling autorun and when running ibaCapture Encoder in MIL mode. #13166
  4. An additional textbox for speed modification has been added to the scenario camera command setup. #13403

Bug fixes (B)

  1. Camera view: it was sometimes necessary to switch between the layout and rule configuration controls in the scenario player properties to load layout changes for the rule configuration.
  2. Camera view: replay synchronization could throw an exception at the initialization of a camera view.
  3. Server: index entries of ONVIF and RTSP sources could get corrupted. #13404

 

Version 4.3.1 - 2018-09-20
Required EUP date - 2018-07-12

Improvements (I)

  1. Camera view: the DateTimePicker of embedded camera views in ibaPDA clients has been updated to match the DateTimePicker in ibaCapture Manager. #12097
  2. Manager: a button, which allows browsing for a layout file, has been added to the ibaCapture Manager settings form. #13114
  3. Encoder: upgraded CVB dependencies to v13.01.0002. #13180
  4. A watchdog can be configured for AXIS cameras which will monitor the frame rate and restart the stream if the frame rate falls below the configured threshold over a configured time interval. #12244
  5. Jitter correction has been improved for AXIS, ibaCapture-ScreenCam and ibaVision output cameras. #12070
  6. The engine ID of the SNMP server is now unique. The current value can be seen in the diagnostics tab on the SNMP node in the server configuration. #13364
  7. Searches for ibaCapture servers can now cross routers. #13398

Bug fixes (B)

  1. Camera view: creating an instance of a Cossilys player would result in uncaught exceptions. #13377
  2. Player: ibaCapture Players using GDI would not automatically try to switch back to DirectX. #12729
  3. Player: port exhaustion could occur if players required a login. #13162
  4. Player: synchronization groups with only one member would not be removed automatically from the ActiveX replay synchronization.
  5. Manager: the behavior of the storage path control was inconsistent. #12970
  6. Manager: skipping forward to the storage settings without selecting a camera type in the camera configuration wizard, resulted in a crash. #13084
  7. Encoder: the initialization of Intel Quick Sync encoders would fail when combined with monochrome cameras. #13080
  8. Encoder: certain GigE Vision cameras appear to be missing a frame rate property, which results in the Intel Quick Sync encoder failing to initialize. #13081
  9. Encoder: ibaCapture Encoder would fail in CVB mode if the installed Common Vision Blox Manager version was different from v13.00.0006. #13180
  10. Encoder: ibaCapture Encoder was incompatible with eBUS SDK versions other than v5.1.5. #13399
  11. Server: the ibaCapture Server would sometimes try to initiate RTSP streams with incorrect URIs. #13262
  12. Server: an ibaCapture Server could apply multiple configurations to one ibaCapture-ScreenCam instance at the same time. (Fixed in v4.1.2, reintroduced in v4.2.0.) #13336

 

Version 4.3.0 - 2018-07-12
Required EUP date - 2018-07-12

New features (N)

  1. Encoder: Stemmer Imaging CVB Image Manager SDK is now supported for GigE Vision cameras. #11752
  2. Encoder: Pleora eBUS SDK is now supported for GigE Vision cameras. #11752
  3. Encoder: TurboDrive is supported for Teledyne Dalsa GigE Vision cameras through CVB. #9120
  4. Encoder: NVIDIA encoding is supported for eBUS/CVB GigE Vision cameras. #7705
  5. Manager: a new property in the ibaCapture Manager settings allows the ibaCapture Manager to automatically switch to live view on startup. #11827
  6. Offline processing is supported for virtual cameras. To allow synchronization later on, an offline virtual camera needs to be configured on the same ibaCapture Server as the synchronization master camera in the ibaVision program. #12028
  7. Spanish localization resources have been added.
  8. The embedded metadata of exported videos contains the recording date. This value can be found in the QuickTime property ContentCreateDate ('©day') in the user data atom ('udta') of the MP4. #12967

Improvements (I)

  1. Manager: a default layout can be set which will be used on start up. #11543
  2. Manager: the validation dialog, shown when applying a configuration, will close automatically after a few seconds if no errors or warnings are detected. #12774
  3. Manager: iba support contact information can be found in the 'About ibaCapture'-form in the ibaCapture Manager.
  4. Active Directory: trusted domains are now supported. #10533
  5. Updated dongle driver installer to v1.8.18.416.

Bug fixes (B)

  1. Manager: the ibaCapture Manager would save configurations in v3 format with default storage settings. (Bug introduced in v4.1.2) #12716
  2. Manager: when applying a configuration it was possible to receive notifications about a video format change for cameras without a specified storage directory.
  3. Manager: warnings about unavailable functionality could pop up if the ibaCapture Server status was anything other than 'Running'. #12834
  4. Manager: when opening the settings of a disconnected AXIS camera, the configuration of this camera would get reset when applying the configuration. #12976
  5. Camera view: after triggering a rule in the scenario player, ibaCapture players would not jump anymore when double-clicking an ibaHD event. #12756
  6. Camera view: a crash could occur due to a bug in the replay synchronization algorithm.
  7. Camera view: certain jump operations would not work after pausing a live view. #12919
  8. Player: in some cases players would not restart livestreaming after an error. #12666
  9. Player: a crash could occur when trying to display a video stream with a 16-bit color depth. #12917
  10. Server: frame timestamps from ONVIF and/or RTSP sources would sometimes be set to future dates. #12717
  11. Encoder: invalid widths/heights could slip unnoticed through the Intel Quick Sync encoder validation. This could result in crashes later on. #13057
  12. Failed Active Directory logins could show misleading error messages. #12589
  13. Overwriting a file during export could result in the file containing the new video and garbage data of the old contents. #13058

 

Version 4.2.2 - 2018-03-15
Required EUP date - 2017-12-13

Improvements (I)

  1. Camera view: pausing the players on time jumps can be disabled with a new property in the properties dialog. #12327
  2. Player: players can now read embedded video files. #10979
  3. Manager: when entering a host name as address in ibaCapture-ScreenCam camera settings, it was automatically resolved to its corresponding IP address. Resolving has been removed and both host names and IP addresses are supported. #12522
  4. Manager: a button has been added to the storage configuration to force a storage reinitialization. #11874

Bug fixes (B)

  1. Server: GigE cameras with ibaPDA-activated recording would not record. #12514
  2. Server: ibaCapture Servers with ONVIF or RTSP sources could crash if the calculated fps was negative. #12403
  3. Server: there were still cases where storage would keep using files with an incorrect size. #11874
  4. Encoder: stored camera resolutions in the configuration file would overwrite new settings. #12351
  5. Manager: applying valid ibaCapture-ScreenCam settings could sometimes result in an error stating that the camera could not be found. #12539
  6. Player: initializing players while the server is unreachable could cause the host application to hang. #12452
  7. Camera view: focus handling wasn't correct when closing signal selection in trigger editor of scenario player. #12329
  8. Camera view: authentication would not persist in the scenario player. #12337

 

Version 4.2.1 - 2018-02-01
Required EUP date - 2017-12-13

Improvements (I)

  1. Manager: the selection of SNMP fields is enabled. #12081
  2. Manager: options for adding local users and local user groups have been added to the dropdown menu of the buttons in the server configuration. #12214
  3. Manager: double-clicking a camera view layout file (.CCL) will load the file in a new ibaCapture Manager instance. Previously, an ibaCapture Manager instance would open with the last used layout. #11824
  4. Manager: add a camera view layout file (.CCL) path as an argument when starting ibaCapture Manager from the command line to load this layout. #11824
  5. Manager: load ibaCapture Manager with a certain ibaCapture Manager layout file using the command line argument /M:[FILE_PATH]. Use an absolute path to allow storing changes to this file. #12294
  6. Camera view: jumps caused by ibaHD events and the time picker pause the players. #12327
  7. Player: replay synchronization has been added to the ActiveX component. #12285
  8. The authentication process has been sped up with the use of caching. #12179
  9. The synchronization of ONVIF and RTSP sources has been improved. #11992

Bug fixes (B)

  1. Installer: .MP4-files could not be played on a 32-bit Windows Media Player. #12159
  2. Installer: in rare cases, the ActiveX component of ibaCapture Player would not be registered successfully during installation. #12193
  3. Manager: ibaCapture Manager could crash due to an uncaught exception. #12173
  4. Manager: ibaPDA Client could hang during exit if the ibaCapture Manager was opened #12243
  5. Manager: ibaCapture Manager would sometimes load on a different display monitor or with different dimensions than stored in the configuration file. #12294
  6. Camera view: the active replay master would frequently change when jumping to next or previous events. #12250
  7. Camera view: the properties dialog height was too low. #12328
  8. Camera view: jumping to next/previous events and starting replay could result in no video being shown. #12314
  9. Camera view: the properties dialog showed the property 'Replay speed after time jump', which is obsolete. #12327
  10. Player: exporting videos could fail due to a bug in the MP4 multiplexer. #12183
  11. Server: sometimes the status application would not exit automatically during uninstall. #12201

 

Version 4.2.0 - 2017-12-13
Required EUP date - 2017-12-13

New features (N)

  1. An ibaCapture Server Status application will show the current state of the ibaCapture Service. Through this application the service can be started, stopped or restarted. As a result of this, the functionality related to the service has been stripped from the ibaCapture Manager. #10964
  2. PTP support has been added. This can be configured via the time synchronization node in server configuration mode. #7487
  3. ibaCapture is an SNMP server: #8716
    1. SNMP protocol V1, V2c and V3 are supported.
    2. MIB files can be generated.
  4. Live view priorities: #10031
    1. In the server configuration under Server Acccess Control it's to possible to set live view priorities based on client names.
    2. The following wildcards can be used in the client names: ?, +, *.
    3. Negative priorities are accepted.
  5. Expiration dates of extended update periods are checked: #10256
    1. The installer will check if ibaCapture's build date lies before the end of the extended update period. If this is not the case and a grace period is available, the user has the option to activate the grace period and use the software for a limited period. If there is no grace period available or in case it expires, ibaCapture will be disabled.
    2. Warnings are shown in ibaCapture Manager if a server license approaches an expiration date.
    3. The expiration date of the extended update period as well as the remaining days of the grace period are displayed in ibaCapture Manager.
  6. Manager: buttons for increasing and decreasing the replay speed have been added to the ribbon. #11148
  7. Manager: buttons for hopping to the next or previous event on a timeline have been added to the ribbon. An event is defined as one of the following occurrences: #11148
    1. The first or last frame received.
    2. The start or end of a protected video.
    3. The start or end of a locked video.
  8. Server configuration: AXIS camera discovery has been added. #10904
  9. Server configuration: an option to delete the video storage when removing a camera has been added. #10807
  10. Server configuration: a 'General settings' node has been added under the 'Camera configuration' node. On this node general camera settings (e.g., the default root path for camera storage) can be set. #11806

Improvements (I)

  1. ibaCapture Server has been upgraded to a 64-bit process. This results in a reduced risk of virtual address space fragmentation. A 32-bit ibaCapture Server will be still available for 32-bit systems. #11635
  2. Manager: rearrangement of the ribbon layout. #11148
  3. Manager: setting the replay speed to 0 is disabled. #11148
  4. Manager: the layout of the server overview is saved. #8926
  5. Manager: Quick Access Toolbar changes are saved. #8871
  6. Manager: page category captions have been removed to increase the size of the Quick Access Toolbar. #8871
  7. Manager: in fullscreen mode the ribbon toolbar will hide after 2 seconds. #11448
  8. Manager: unwanted entries in the list of previously used camera layouts can be removed through the context menu. In addition to this, the user will be asked if a lay-out file should be removed when it cannot be opened. #11326
  9. Manager: automatic ribbon page switches have been removed. #11711
  10. Manager: when adding a new camera, the default file size will depend on the resolution (if available). #10833
  11. Camera view: when changing the speed using the slider in a scenario rule set-up, the actual value is shown in a ToolTip. #10732
  12. Player: horizontal and vertical flipping has been exposed in the ActiveX Player. #10422
  13. Player: lag caused by an RTP timestamp overflow has been removed. #11992
  14. Server configuration: if user management is enabled, the username for active connections is shown in the status control. #10026
  15. Server configuration: panic activation is now a global permission. A user who only has this global permission granted, will not be able to open the server configuration. #11392
  16. Server configuration: the region dimensions of an HMI camera can now be set using editable controls. #11586
  17. Server: when changing the storage location of a camera, the old directory (if available) will be moved towards the new location. This way, old footage remains available in the new configuration and no manual deletion of the old storage location is required. #11797
  18. Encoder: the amount of error logging has been reduced. #11647

Bug fixes (B)

  1. Manager: the 'Tab' and 'Alt' buttons of an AXIS keypad work again as intended. #11768
  2. Manager: several controls showed a context menu on a right-click, which allowed them to be modified. #11881
  3. Manager: the button 'Force live view' was only applied to the selected players. #11148
  4. Manager: panning would not work anymore in ibaCapture Manager. #12076
  5. Manager: when using floating points in combination with the relative storage unit '%', these will be truncated to integers in the server. To allow backwards compatibility, the input in ibaCapture Manager is restricted to integers when using the relative unit. #12077
  6. Player: some bugs related to the player synchronization have been fixed. #11422 #11423 #11424
  7. Player: removal of a player could result in a crash. #11718
  8. Player: in some cases the displayed video would randomly stretch. #11771
  9. Player: exporting mpeg-4 encoded streams would result in unplayable files. #11990
  10. Player: resizing a player while paused could lead to a black display. #12072
  11. Server: in some cases trying to export videos would fail due to not having the right permissions while user management was disabled. #11706
  12. Server: changing the file size could result in an incorrect storage initialization. #11874
  13. Server: exceptions would be logged when starting a live stream while the server is shutting down. #11870
  14. Server: ONVIF sources could receive streams from cameras other than the configured one due to older incorrectly closed sessions. #12098
  15. Server: applying configurations to two or more HMI instances with the same name on different hosts would result in errors for all but one instance. #12109
  16. Installer: during the installation of ibaCapture on 64-bit systems, the first logging was always written to the install history in the wrong directory. #11701
  17. Installer: in some cases the option to manually reboot later on would have no effect. #12106
  18. Several localization bugs are fixed. #10952 #10953 #10954 #11004 #11005 #11006 #11007 #11008 #11009

 

Version 4.1.2 - 2017-09-14

New features (N)

  1. ibaCapture supports .NET Framework 4.7.1.

Improvements (I)

  1. Manager: F10 can be used again as hotkey for cycling through the different screen modes. #11447
  2. Manager: if a server configuration is opened on another host, the warning will now show the client name (if available) instead of the IPv6 address. #11395
  3. Manager: warnings will be shown if the 'Stop service'- or 'Stop capture'-buttons are clicked in the server configuration. #11612
  4. Manager: the settings of HMI cameras can be changed immediately. In previous versions the discovery had to finish first. #11646
  5. Installer: to assure other applications are made aware of the new installation of ibaCapture, the user will be asked to reboot to complete the installation. #11366
  6. Player: reduced the amount of logging for the players if a login is required. #11649

Bug fixes (B)

  1. Camera view: joystick configuration settings (sensitivity, threshold, etc.) weren't applied. #11582
  2. Camera view: an ibaCapture Server could apply multiple configurations to one ibaCapture-ScreenCam instance at the same time. #11602
  3. Player: a memory leak could occur when using ibaCapture Manager remotely. #11577
  4. Player: a false detection of a lost device would repeat forever. #11578
  5. Installer: copying the remaining data files when upgrading from v3 to v4 would still fail on 32-bit systems. #11083
  6. Installer: ibaVision and ibaCapture Encoder would be restarted after installation of ibaCapture, even if they were not killed by the installer. In addition to that, they wouldn't show up in the list of blocking processes. #11428
  7. Installer: on 64-bit systems the installer would try to copy the DirectX DLL to the wrong system directory. As a result of this ibaCapture Manager would crash. (Bug introduced in v4.1.1) #11672
  8. Manager: when switching the capture settings of HMI cameras to 'Monitor', it was possible to choose the invalid monitor ID '0'. #11507
  9. Manager: when selecting a region for HMI cameras, an extra pixel would be added to the width and height of the selected region. #11506
  10. Manager: trying to login with wrong credentials while being in the server configuration would result in a state where no user is logged in. This was not visible, but some buttons would not function correctly anymore because of this. #11454
  11. Manager: server configuration could not be opened if the ibaCapture Server reported an error. #11612
    Note that this is still the case if the ibaCapture service is stopped!
  12. Manager: inherited permissions would not be checked when opening a server configuration. #11629
  13. Manager: the MAC address would be changed to the first discovered camera when opening the settings of a GigE camera. #11643
  14. Manager: in some cases an ID, which at that time was already in use, would be assigned to a newly added camera. #11686

 

Version 4.1.1 - 2017-07-26

Improvements (I)

  1. Manager: in case user management is enabled, the user is now required to login before the configuration control is shown. #8812
  2. Manager: warnings are shown when no or an invalid password has been entered or when the user does not have the required permissions for opening the configuration control. #10962 #8812
  3. Manager: the ToolTip of the status bar in the configuration control has been updated to show which permissions are acquired when a user with limited permissions is logged in. #11131
  4. Camera view: a warning will now be shown when removing one or multiple cameras using the [DEL] button, the 'Remove'-option in the context menu or the 'Remove selected cameras'-button in the ribbon. The user can also choose to disable this warning. Re-enabling the warning can be done via the properties control. #10587
  5. Camera view: a warning is shown if a user is not allowed to use PTZ control. In this case, the crosshair won't be shown either. #10961
  6. Installer: in case the dongle has an invalid EUP end date, a warning is shown upon installation of ibaCapture. #10256
  7. Installer: the installation of ibaDongleViewer can be disabled during a silent installation of ibaCapture with the command line switch '/nodongleviewer'. #11281
  8. Opening Matrox Intellicam requires ibaEncoder to be stopped. In some cases, trying to stop ibaEncoder results in an exception. Additional information has been added to the exception in which the user is asked to try to manually stop ibaEncoder and retry opening Matrox Intellicam. #10661

Bug fixes (B)

  1. Camera view: disposing the camera view could lead to uncaught exceptions. #11047
  2. Camera view: after exporting a video, the involved players kept showing "No connection to server". #10963
  3. Camera view: when using an AXIS jog dial, the speed increments were too large. #11254
  4. Camera view: when using an AXIS jog dial, speed changes were not reflected in the camera controls. #11252 #11253
  5. Support tool: ManagerConfig.xml and CurrentLayout.ccl were not included when creating a support file. #11036
  6. Server configuration: the 'Open Matrox Intellicam'- and 'Open Matrox Capture Assistant'-buttons were missing in the settings control of GigE Vision cameras. #11267
  7. Server configuration: a duplicate 'Apply configuration'-button was shown in the ribbon page for GigE Vision. #11267
  8. Server configuration: an unused 'Pixel Conversion'-control was shown in the settings control of GigE Vision cameras. #11396
  9. Encoder: meaningless text was shown in the 'GigE'-tab. #11425
  10. ibaCapture install could possibly fail without warning on Windows 7 SP1 X64 systems. #11208
  11. When upgrading ibaCapture from v3 to v4 the remaining data files (e.g., logs, dumps, configurations) were not copied to the new directory. #11083
  12. The 32-bit ibaCapture Manager remained installed when upgrading to a 64-bit Manager.
  13. On some systems the configuration of ibaCapture Server was disabled. #11142

 

Version 4.1.0 - 2017-05-18

New features (N)

  1. Support for multiple live streams: #8662
    1. These can be used to dramatically reduce the CPU load of clients showing live video from lots of cameras.
    2. Supported on AXIS, ONVIF and RTSP cameras.
    3. The player can switch automatically between the different live streams depending on its size.
    4. An alternative live stream is only started when at least one player uses it.
  2. Camera view: double-clicking a camera toggles between maximized and normal view. #8874
  3. Manager: The user can easily switch between previously loaded ibaCapture layout files. #10641
  4. New command line switch for installer: /player to install only the player. #10877

Improvements (I)

  1. Panic mode can be switched off from the ibaCapture manager. #10050
  2. Throughput values of the video connections in the ibaCapture manager are expressed in bit per second instead of byte per second. #10808
  3. Camera view: When the timestamp picker is closed with the OK button then the jump is executed even when the timestamp hasn't changed. #10585
  4. Disabled cameras are no longer shown in the tree of the ibaCapture manager. #10879
  5. Display-only and virtual cameras can use normal recording camera licenses when there are no more display-only or virtual camera licenses left. #10878
  6. Manager: The display of the license info has been changed to reflect the current configuration you are editing instead of the configuration running on the server.
  7. Manager: Confirmation is asked before applying the storage configuration to all cameras. #10593

Bug fixes (B)

  1. Camera view: The form used to protect/lock video updated the incorrect nodes when not all servers were selected.
  2. Camera view: Disabled cameras caused a jump to 1/1/1970 when pausing the video.
  3. Camera view: Rearranging cameras caused a painting bug in the time line when it was docked and collapsed. #10810
  4. Camera view: Changing the replay speed via the arrow keys could result in a stackoverflow in ibaPDA.
  5. Camera view: Using PAGE UP and PAGE DOWN keys to jump in time when the replay speed was not zero resulted in very large replay speeds.
  6. Video from Bosch cameras would behave as keyframes only video when jumping to a timestamp or playing backwards. #10812
  7. Negative throughput values could be shown for the video connections in the ibaCapture manager. #10464
  8. The calculation of the ibaPDA synchronization period could lead to very small values that caused high network traffic between ibaCapture and ibaPDA. #10831
  9. ibaCapture service ran out of memory when no key frames were coming in for a long time. This could happen when there was packet loss in the RTP stream. #10870
  10. After losing the connection to an ibaCapture-ScreenCam, frames could be parsed incorrectly once the connection was restored again.
  11. The connector number on Picolo U8 cards was limited to 4 instead of 8 by the ibaCapture manager. #10881
  12. The silent installer didn't work correctly on 64 bit systems. #10902
  13. Manager: Panning in the camera view didn't work after a load of an ibaCapture layout configuration. #10892
  14. AXIS camera: The server didn't consider changes in GOP size or framerate as configuration changes.
  15. The player didn't always return the current image. This resulted in missing images in reports generated by ibaAnalyzer or in missing image triggers in ibaPDA. #10938

 

Version 4.0.5 - 2017-04-18

New features (N)

  1. ibaCapture server supports .NET Framework 4.7. #10723

Bug fixes (B)

  1. ibaCapture manager didn't start when the VC++ 2010 runtime wasn't installed (bug introduced in 4.0.4). #10721
  2. The timeout for new video frames was too low for HMI cameras recording at 1 fps. #10631
  3. Video export generated keyframe only video files for high speed cameras (bug introduced in 4.0.0). #10695
  4. The configuration was always invalid when more than one display only camera was configured. #10674
  5. Memory diagnostics were written as error in the event log. #10624

 

Version 4.0.4 - 2017-03-23

New features (N)

  1. ibaCapture Manager is installed as a 64-bit process on a 64-bit operation system
  2. ibaEncoder is compatible with MIL-Lite 10.00 R2 (build 2995)
  3. It is possible to turn off the sending of keep-alive requests to RTSP cameras and ONVIF cameras
  4. ibaCapture camera view is installed as part of the ibaCapture player. This means that ibaPDA 6.37.4 or higher can load the most recently installed camera view.

Improvements (I)

  1. When replaying video on multiple players, all players are synchronized to the same clock
  2. The context menu of the timeline markers is displayed when the settings icon (gear) is clicked instead of when the mouse hovers over it
  3. ibaCapture camera view: It is now configurable what happens when replay catches up with the live video

Bug fixes (B)

  1. Sometimes the camera name on a player was not drawn correctly
  2. The speed slider in the Camera Command dialog of the rules editor was truncated
  3. ibaEncoder unloaded the MIL when one of the connected cameras was not valid
  4. ibaEncoder could crash when stopping or starting grabbing
  5. The context menus in ibaCapture manager were closed when a submenu-item was selected
  6. The player's replay mode was not correctly updated when its previous mode was the NoRecords mode
  7. ibaCapture camera view didn't go to live mode when it got the start command from ibaPDA
  8. The player remained in key frames only mode for some time when switching from a high speed (> 4x) to a low speed (< 4x)
  9. New video files for different cameras were created in parallel. This lead to disk fragmentation.
  10. The initialization of the video storage couldn't be interrupted.
  11. The camera input selection on an AXIS video encoder didn't work.

 

Version 4.0.3 - 2017-02-15

Improvements (I)

  1. Change the filename of the version history to versions_cap.htm

Bug fixes (B)

  1. Replay speeds are not set (bug introduced in 4.0.2)
  2. When connecting to an RTSP device that also supports audio streaming, bad settings could be loaded in ibaCapture
  3. ibaCapture player 64-bit showed an error message "Cannot create directshow graph" when it was installed by another user
  4. ibaCapture server was not stopping ibaCapture encoder correctly
  5. The layout editor in scenario player was not using all available space
  6. The rules editor in scenario player had no tooltips on its buttons

 

Version 4.0.2 - 2017-01-25

Improvements (I)

  1. The log file size can be limited

Bug fixes (B)

  1. Critical errors in MIL are handled by the ibaCapture encoder
  2. Domain authentication failed when it was performed at a client on Windows 7 connected to a domain controller on Windows Server 2012
  3. When the next/previous image commands were triggered by the CTRL-Left/CTRL-Right hotkeys then the configured replay speed was not taken into account
  4. The option "Auto-start when Windows starts" didn't work in the ibaCapture encoder
  5. ibaCapture player could crash due to an OutOfMemory exception. This occurred especially when there were many players playing backwards.

 

Version 4.0.1 - 2017-01-12

Improvements (I)

  1. Support recursive group membership in Active Directory for users which are not mapped in ibaCapture security management
  2. ibaCapture server creates a new logfile for user management logging
  3. The connection between ibaCapture server and HMI service is performed on IP-address base
  4. Include eventviewer logs in the support file

Bug fixes (B)

  1. The slider for changing the replay speed did not fit in the toolbar of camview
  2. The disk information of a server was not re-initialized when the server was not connected at the moment ibaCapture Manager was started
  3. The video lost timeout for GigE settings was not saved correctly
  4. Changes in the digitizer configuration file were not applied when its filename was not changed
  5. An unjustified error was prompted when ibaEncoder was already stopped and Intelicam opens from ibaCapture Manager
  6. The current live view layout was cleared completely when the open file dialog which browses to a layout file was canceled
  7. Persist the login of the current windows user
  8. Fix for crash in ibaPDA IO manager while previewing HMI cameras
  9. Fix for crash in ibaEncoder when an invalid GigE camera is connected

 

Version 3.7.8 - 2017-01-04

New features (N)

  1. The version upgrade xml file contains the number of PDA connections

Bug fixes (B)

  1. The support file did not contain the server loggings on a x64 platform

 

Version 4.0.0 - 2016-10-31

.NET Framework 4.5.2 or later is required

The dedicated camera interfaces for Sony and Panasonic have been removed from ibaCapture.
If supported by the camera, ONVIF can be used as an alternative.

New features (N)

  1. Increased maximum number of cameras to 64
  2. New licensing model based on total configured frame rates with scalable server license options
  3. ActiveDirectory integration for easier user management
  4. User management offers group-based authorization for local and ActiveDirectory groups
  5. New design and handling of ibaCapture Manager application
  6. Support for ibaCapture-HMI V4
  7. Support for ibaVision virtual cameras
  8. Interface licenses for ibaPDA connections are now handled by ibaCapture Server. Using ibaPDA v6.36.6 or later is recommended.

Improvements (I)

  1. Only cameras with changed configuration will be re-initialized when applying a configuration to the server
  2. ibaCapture Manager can now configure remote ibaCapture Servers
  3. Speed range for video playback is now -50x to 50x
  4. Timeline can now be collapsed to leave more space on screen for cameras
  5. The configured cameras will start up in parallel when applying a new configuration or at ibaCapture Server startup

Bug fixes (B)

  1. Applying configuration during server starting/stopping could lead to undefined behavior
  2. Messages sent by the server during validation could be shown unsorted
  3. Player: artefacts when resizing the control
  4. Fix for parsing RTSP session description attributes

 

Version 3.7.7 - 2016-10-26

Bug fixes (B)

  1. ibaPDA could not load ibaCapture-CAM player

 

Version 3.7.6 - 2016-10-24

Improvements (I)

  1. The percentage of dropped frames is shown in the debug overlay of the ibaCapture-CAM player
  2. Double click on the player control while holding the CTRL-key to reset the number of rendered and dropped frames in the debug overlay of the ibaCapture-CAM player

Bug fixes (B)

  1. When multiple instances of ibaCapture-CAM Manager are opened at the same moment, an error occurred while opening the logfile
  2. ibaCapture-CAM crashed when certain updates of the .NET Framework were installed (KB3179930, KB3179949, KB3135994, KB3186208)
  3. ibaCapture-CAM service crashed because of excessive logging when the maximum number of pages in the frames bufferpool was exceeded

 

Version 3.7.5 - 2016-09-22

Improvements (I)

  1. Add option to enable quick server startup by skipping the index file consistency
  2. Add debug option to dump version upgrade information
  3. The maximum allowed buffer pages in the frame pool are determined dynamically

Bug fixes (B)

  1. When stopping a stream from a Sony network camera an exception could occur
  2. Time synchronization with RTSP streams didn't always work correctly
  3. ibaCapture-CAM Manager couldn't start in full-screen mode when the command line contained a layout file
  4. The last zoom position of an ibaCapture-CAM player was not correct after loading the layout
  5. RTSP packets bigger than 1536 kB caused a crash of the server
  6. Bugfix in RTP packets compiler

 

Version 3.7.4 - 2016-07-06

New features (N)

  1. Installer includes 64-bit player and ActiveX
  2. Upgrade ibaDongleViewer to v1.6.2

Improvements (I)

  1. Connect to Onvif compatible devices with digest HTTP authentication
  2. Control if the frames which do not fit in a file should be dropped on disk or not (debug option)
  3. A warning is shown in ibaCapture-CAM Manager when frames were found which do not fit in a file

Bug fixes (B)

  1. When an Onvif compatible device did not support all coordinate systems (PTZ spaces), an error occured
  2. The URI of the retrieved coordinate systems for PTZ was not applied
  3. The retrieved timeout duration for PTZ was not applied
  4. Fix for parsing RTSP session description attributes

 

Version 3.7.3 - 2016-04-26

Improvements (I)

  1. Show progress when getting the amount of videofiles for a certain camera. In previous versions, the progress was frozen at 90%
  2. Server: Increase the size of the streaming buffer to allow more clients to connect

Bug fixes (B)

  1. Server: Could not start when invalid characters were present in the camera name
  2. By applying the local date and time formats on the time picker of the camera view (bugfix in Version 3.7.2), the button to show the dockline on the time picker disappeared
  3. Server: Could not connect to certain RTSP or Onvif sources that returned HTTP status 460 when trying to start the video stream
  4. Could not connect to an Onvif Compatible Device with a port number other than 80
  5. Server: Additional parameters in the RTSP URI could be ignored in case the camera didn't provide an explicit URI to the video stream
  6. Server: Disable automatic defragmentation of video files. This was the case when the indexfile was rebuilt or video files were deleted after decreasing the storage
  7. Export form shows localized datetime formats
  8. Server: AXIS cameras which are connected by http via their hostname could not reconnect when their IP address changed.
  9. Server: when the server cannot setup a livestream with dynamic ports (Tcp), its already reserved bufferpages were not cleared.
  10. Onvif device discovery was not able to detect some Samsung devices
  11. A GDI+ exception was not handled in ibaLiveView
  12. Filter the link-local IP address out from the list of the Onvif discovered IP addresses
  13. VAPIX: the PTZ presets were mixed up if the Data-line came before the Name-line in the VAPIX response
  14. VAPIX: the PTZ limits were requested from the videochannel, while the presets were interpolated using the limits from the device parameters

 

Version 3.7.2 - 2015-11-30

New features (N)

  1. Camera view supports the AXIS Video Surveillance Control Board (T8310):
    1. T8311: AXIS Video Surveillance Joystick
    2. T8312: AXIS Video Surveillance Keypad
    3. T8313: AXIS Video Surveillance Jog Dial

Improvements (I)

  1. AXIS IP camera configuration accepts a maximum GOP size of 200 and a maximum frame rate of 60 fps
  2. Server: Extra consistency checks of the index file
  3. Server: The configuration file is backed up when a new server configuration is applied
  4. Add a warning message on the new button in LIVE view, to avoid accidental configuration losses
  5. Maximizing a camera (making a camera prominent) no longer unselects the other cameras
  6. Camera recording control now supports different cameras controlled by multiple ibaPDA systems. ibaPDA version 6.34.6 or higher is required.

Bug fixes (B)

  1. Server: Could not connect to certain RTSP sources (additional cases since bug fix in 3.7.0)
  2. Additional check if ONVIF url is valid
  3. Apply local date and time formats on the time picker of the camera view
  4. Infotext overlay alignment could not dock to the bottom center position
  5. Server: Applying more than one camera with the recording mode "Never" resulted in an error that the same directory was used
  6. Server: Frames with a size bigger than the size of the video file will be ignored

 

Version 3.7.1 - 2015-10-26

Improvements (I)

  1. Added ibaDongleViewer v1.5.3 to setup to avoid false positives from Antivirus packages

 

Version 3.7.0 - 2015-08-10

New features (N)

  1. Added ibaDongleViewer to setup

Improvements (I)

  1. Revised GigE camera support
  2. Support: Added some extra information to the system information file
  3. Support for .NET Framework 4.6
  4. Updated ffdshow codec pack to version 1.3.4531 (released 2014-06-28)

Bug fixes (B)

  1. Server: Could not connect to certain RTSP sources (additional cases since bug fix in 3.6.5)
  2. Updated dongle library to prevent incorrect missing dongle errors when multiple iba products try to access the dongle at once
  3. Could not connect to certain ONVIF sources that required authentication
  4. Server: Certain test firmware versions on AXIS cameras were not properly recognized
  5. Server: When connecting to an AXIS camera using a host name, the server could not reconnect after the underlying IP address was changed

 

Version 3.6.5 - 2015-02-09

Bug fixes (B)

  1. Server: Could not connect to certain RTSP sources (additional cases since bug fix in 3.6.4)
  2. Server, Player: Fixed possible crashes caused by incorrect video frame reference counting (bug introduced in 3.6.4)

 

Version 3.6.4 - 2015-01-21

Bug fixes (B)

  1. Server: Could not connect to certain RTSP sources (some cases introduced in 3.6.2)
  2. Server: Fixed memory leak for cameras where frame loss could occur
  3. Server: More robust connection handling between ibaPDA and ibaCapture-CAM
  4. Manager: Image adjustment controls were incorrectly displayed for ONVIF compatible devices and RTSP sources
  5. Manager: When exporting the entire configuration to XML, the settings of the currently selected camera were not saved
  6. Manager: Full screen on all monitors didn't work when primary monitor wasn't on the left

 

Version 3.6.3 - 2014-10-29

Bug fixes (B)

  1. Player: Fixed possible crash caused by incorrect video frame pool allocation
  2. Server: Fixed possible crash caused by incorrect video frame pool allocation
  3. Camera view: Fixed multiple memory leaks

 

Version 3.6.2 - 2014-09-18

Improvements (I)

  1. Updated AXIS Media Parser to version 3.62
  2. Video Encoder uses Intel® Media SDK 2014 for Clients
  3. Removed two encoder options from the configuration: Encoding Profile and Encoding Level. Applies to GigE camera type

Bug fixes (B)

  1. Encoder: Changed the way ibaEncoder submits the frame to the encoder, new hardware (4th generation of Intel® CPU's) doesn't like when it is forced to use the frame type for the submitted frame
  2. Server: When "Key frames only" option is used by the player in replay mode then the server sends incorrect messages
  3. Server: Video frame allocator can throw OutOfMemory exception in certain circumstances
  4. Server: Some RTSP packets can provoke IndexOutOfRangeException at RTSP client and stopping the service
  5. Server: video frame's timestamp correction not worked as desired (AXIS and CNB camera types)
  6. Server: SONY camera do not connects after Windows security update from 11/06/2014
  7. Server: RTSP communication with old versions of BOSCH encoder device.
  8. Manager: When opening ONVIF Profile editor an exception could be thrown
  9. Manager: Profile settings information is not updated in ONVIF camera config control after editing video encoder configuration
  10. Manager: Camera controls and configuration tree were not properly updated after service stop/start
  11. Manager: /live command line switch caused a crash
  12. Manager: Crash when closing multiple instances at the same time
  13. Camera view: Crash when displaying live video from ibaCapture-CAM v2 servers
  14. Camera view: PTZ control didn't work anymore after 1 minute of inactivity

 

Version 3.6.1 - 2014-04-30

Bug fixes (B)

  1. Player: Video distorted on some old Intel express chipsets.
  2. Player: Incorrect timestamp returned when play direction switched in replay mode.
  3. Some RTSP sources with absolute URL's in both session and media descriptions, cannot be played.
  4. AXIS camera firmware parsing when firmware string contains non-numeric characters.
  5. Some RTSP sources with rare URL's cannot be played.

 

Version 3.6.0 - 2014-01-30

New features (N)

  1. PTZ control:
    1. PTZ control for AXIS cameras. AXIS camera requirements: firmware 5.20 and higher, VAPIX 3 and higher.
    2. PTZ control for ONVIF compatible devices
  2. Manager: added two screen modes in Camera View (enlarged, fullscreen). Switching between the screen modes occures by pressing F10 button. If more than one screen is available then the mode 'full all screens' added as extra 4th screen mode.

Improvements (I)

  1. Player: Added support of two formats for video rendering: NV12 and YV12 (Only YUY2 was supported before).
  2. Video Encoder uses Intel® Media SDK 2013
  3. Updated ffdshow codec pack to version 1.3.4500 (released on 2013-01-06).
  4. Updated AXIS Media Parser to version 3.60.
  5. Video writer: the write operations from all cameras are made successive and without system buffering.
  6. All passwords in configuration file are encoded.
  7. ONVIF client: improved support for ONVIF compatible cameras.
  8. Camera view: added icon showing recording status for each camera.

Bug fixes (B)

  1. Camera view: DateTime picker uses now current culture info.

 

Version 3.5.2 - 2013-11-04

New features (N)

  1. When camera recording mode set to Never, camera storage not initialized and the directory is not created if it not exist already.

Improvements (I)

  1. Workaround for cameras which are non conform to RTSP standard, e.g. video stream setup contains no session id.
  2. RTSP client can get video streams from more camera types and models which are expecting the "magic number" from player to identify the byte order (little-endian/big-endian) of the platform on which player runs.
  3. Camera view: Minimum time range in timeline of camera view is set to 50ms (for high frame rate cameras).

Bug fixes (B)

  1. ONVIF: discovered device information contains now more reliable IP address for the device configured with several IP addresses, e.g. AXIS cameras with Zero config option enabled.
  2. RTSP client: URI parsing and checking port numbers.

 

Version 3.5.1 - 2013-08-26

New features (N)

  1. Live stream mode list extended with 'TCP Active' option. Live video is accessible now on ibaCapture-CAM servers located behind firewall.
  2. Added new camera type: RTSP source.

Improvements (I)

  1. AXIS cameras: better communication with the cameras attached directly to the host.

Bug fixes (B)

  1. CamView: mouse cursor restored properly in pan mode (while holding Alt-key pressed) after clicking outside of the current camera view control and Alt-key was released.
  2. Fixed bug in RTP client when the H264 video stream with non-standard extensions in the header was not playable.
  3. Fixed bug in ONVIF and RTSP sources configuration when MPEG4 stream gets wrong color format.
  4. Fixed bug in RTCP client. Source DNS name now translated into IP address before parsing.
  5. Fixed: Some German language resources were not translated.

 

Version 3.5.0 - 2013-06-03

New features (N)

  1. ONVIF compatible devices support:
    1. Discovery of ONVIF compatible devices.
    2. Modification of ONVIF video profiles and ONVIF Video encoder configurations
    3. Receiving H264 and Mpeg4 video streams according to RTSP standards and using following transport protocols:
      1. RTP over UDP
      2. RTP over RTSP
      3. RTP over RTSP over HTTP
      4. RTP over RTSP over HTTPS
  2. Support tool - to collect log files, configuration files, index files and system information
  3. Camera recording control:
    1. Record always
    2. Record except when disabled by ibaPDA
    3. Don't record except when enabled by ibaPDA
    4. Never
  4. HALCON extension. New HALCON operators:
    1. iba_write_log - write log using ibaLogger library

Improvements (I)

  1. Player: improvement in support of several onboard graphic chipsets (e.g. Q35, etc.)
  2. Manager: Use the mouse wheel to zoom in and out
  3. Manager: Pan zoomed view area by dragging the mouse while holding the Alt-key
  4. Video Encoder implements Intel® Media SDK 2012 R2

Bug fixes (B)

  1. Player: One pixel thick black line at bottom and right side of the video.
  2. Player: Export from file to file was always till end of the source video file
  3. Installer: Added installer's icon in Add/Remove Programs (Programs and Features)
  4. New dongle driver is installed that fixes problems with Intel USB 3.0 ports
  5. Dongle installer wasn't copied to the ibaCapture-CAM server directory when another iba product was running during the ibaCapture-CAM installation
  6. Fixed problem while connecting to the AXIS cameras in some cases, application runned out of free service points and returned 'Login failed' error.

 

Version 3.4.2 - 2013-01-16

Improvements (I)

  1. Server: Overload of the U8 board doesn't cause gaps in the video anymore
  2. Server: Overload of the Picolo Diligent board doesn't cause gaps in the video anymore

Bug fixes (B)

  1. Player: Fixed possible crash in player

 

Version 3.4.1 - 2012-12-12

Improvements (I)

  1. Player: Support for image triggers in ibaPDA

Bug fixes (B)

  1. Server: Communication with ibaPDA could stop for all connected ibaPDA systems when 1 connection was lost
  2. Server: Camera index was reset to 1 when server couldn't connect to AXIS encoder
  3. Player: Possible memory leak when player is overloaded

 

Version 3.4.0 - 2012-10-23

New features (N)

  1. User management
    1. Right to view video
    2. Right to export video
    3. Right to protect/unprotect
    4. Right to lock/unlock
    5. Panic mode
  2. Server: Video older than a configurable number of days can be automatically deleted
  3. Server: New dongle library is included:
    1. Demo licenses are supported
    2. Faster SmarxOS formatted dongles are supported
  4. Halcon: Support for v11.x
  5. Camera view:
    1. Support for user management
    2. Second marker to mark ranges
    3. Protect/unprotect video
    4. Lock/unlock video
    5. New keyboard shortcuts: CTRL+Left (Previous frame) and CTRL+Right (Next frame)

Improvements (I)

  1. Player: Faster rendering in GDI because of improved YUV to RGB conversion
  2. Halcon: Better error messages are generated
  3. Halcon: Support for asynchronous grabbing
  4. Server: 90 and 270 degree rotation is supported on AXIS cameras

Bug fixes (B)

  1. Server: Time synchronization with AXIS and Sony IP cameras was not correct
  2. Server: System time jumps were not handled correctly on AXIS and Sony IP cameras
  3. Server: Better handling of continuous video triggers
  4. Player: Player could be incorrectly zoomed after export to mp4 file in ibaAnalyzer
  5. Player: Player crashed when playing back video with a width that wasn't a multiple of 16
  6. Player: Player used too much memory when exporting to mp4 file
  7. Halcon: DoJump command returned before the command was finished
  8. Halcon: Occasional crash of player fixed
  9. Manager: Camera preview wasn't correctly sized

 

Version 3.3.3 - 2012-09-27

Bug fixes (B)

  1. Server: Loading of video files from AXIS cameras generated by ibaCapture-CAM versions older than 3.0 didn't work

 

Version 3.3.2 - 2012-07-17

New features (N)

  1. Installer has command line switches:
    1. /S: silent installation without user interaction (equivalent to pressing the Next button on every page without changing anything)
    2. /manager: install manager
    3. /server: install server and manager
    4. /encoder: install encoder, server and manager

Improvements (I)

  1. Player: Player can be stopped or closed while it is trying to connect
  2. Server: Reading and writing of video files requires less memory
  3. Encoder: Transfer of video frames between server and encoder is more efficient
  4. Manager: Play speed can be set from -3.9 to 3.9 in steps of 0.1 and between -1.0 and 1.0 in steps of 0.01
  5. Manager: The current time display now also shows the milliseconds

Bug fixes (B)

  1. Player: Replay at -0.1x speed didn't work anymore in the ibaCapture-CAM manager
  2. Player: Fixed rare crash when removing player
  3. Player: Support faster generation of image in ibaAnalyzer when the player can't retrieve any video from the ibaCapture-CAM server
  4. Server: Server could incorrectly report that the dongle was removed when multiple iba products were running on the same PC
  5. Server: Picolo Diligent uses even more frame buffers to prevent dropped frames when PC has peak loads
  6. Server: Better handling of unavailable GigE cameras
  7. Server: Fixed growing number threads and handles each time configuration applies
  8. Server: Fixed "dead" encoder instances after validating configuration in some cases
  9. Server: Fixed encoder crash when configuration applied after switching between remote desktop session and local session
  10. Manager: Time picker up/down button click didn't work properly on Windows 2008 server and Windows 7
  11. Manager: Changing time with the arrow keys in the docked timeline didn't work properly if the time step was small

 

Version 3.3.1 - 2012-03-09

Bug fixes (B)

  1. Manager: Fixed crash when running on german system
  2. Manager: Last columns in diagnostics tables were smaller each time a different camera was selected
  3. Manager: Live configuration file was stored in a directory that required administrator rights
  4. Server: Replay delivered incorrect no records segments when some frames were dropped while recording
  5. Server: Replay streams could be left open when the other side didn't close the connection properly
  6. Player: Player could report the incorrect status just after a goto command completed
  7. Player: Frames could be dropped when using TCP in live mode

 

Version 3.3.0 - 2012-02-10

New features (N)

  1. GigE cameras support:
    1. Hardware or software based realtime H.264 encoder
    2. All GigE Vision compliant cameras are supported
  2. Panasonic IP cameras supported
  3. Manager: Extra diagnostics for cameras

Improvements (I)

  1. Server: Less fragmentation in the managed heap
  2. Server: Much faster loading of index file when there are a lot of segments
  3. Server: Hard disk overload is detected
  4. Player: Auto live stream mode uses TCP if no UDP multicast is configured

Bug fixes (B)

  1. Server: Frame queue for live stream kept growing when player was no longer responding

 

Version 3.2.3 - 2011-12-08

Improvements (I)

  1. Server: Picolo Diligent uses more frame buffers to prevent dropped frames when PC has peak loads

Bug fixes (B)

  1. Player: No records segments in mp4 files and between mp4 files were still not handled correctly

 

Version 3.2.2 - 2011-11-29

Improvements (I)

  1. Player: Faster video export

Bug fixes (B)

  1. Player: Player could crash when fast switching between different cameras in live mode
  2. Player: No records segments in mp4 files and between mp4 files were not handled correctly
  3. Player: Reverse play in keyframes only mode didn't work anymore
  4. Player: Fixed display of black frame just after no records segment
  5. Player: Crash during play back of an exported file when a recorded camera has framerate higher than 70 fps (now limited to 500 fps)
  6. Player: Correct handling of replay errors
  7. Server: Correct handling of replay errors

 

Version 3.2.1 - 2011-10-13

New features (N)

  1. Camera view: keyboard shortcuts in replay mode
    1. left/right keys: jump in time
    2. page up/page down keys: bigger jump in time
    3. up/down keys: faster and slower speed
    4. spacebar: toggle between play and pause

Improvements (I)

  1. General: German resources
  2. Server: AXIS cameras with firmware v4.x and v5.x are supported. Before only firmware v5.x was supported.
  3. Server: AXIS cameras can be recorded without the need for root login
  4. Camera view: Easier to set start and stop time in the video export form

Bug fixes (B)

  1. Server: The video signal was not restored on a Picolo Diligent board when the board went into an unreachable state. Now a reset is performed on the board.
  2. Server: The incorrect version was reported to ibaPDA
  3. Server: The sync UDP connection to ibaPDA could be active even when ibaPDA was no longer reachable. ibaPDA v6.27.0 is required for this fix.
  4. Server: Certain AXIS cameras could suddenly stop sending video without reporting an error. This was not detected by ibaCapture-CAM.
  5. Server: The index file could be missing a lot of data after a power failure
  6. Server: Server could close live sessions when frames were coming in faster than the configured frame rate
  7. Manager: Bitrate and fps were still shown when connection to server was lost
  8. Manager: Camera selection of cameras attached to an AXIS video encoder didn't work
  9. Camera view: Exception could occur during progress of video export

 

Version 3.2.0 - 2011-08-10

New features (N)

  1. General: Sony IP cameras are supported

Improvements (I)

  1. Manager: IP cameras have a hyperlink to the camera's website
  2. Camera view: The time picker and the marker in the docked time line always point to the same time stamp
  3. Player: Zoomout can be done via context menu

 

Version 3.1.8 - 2011-07-05

Bug fixes (B)

  1. Server: Memory leak in calculation of bitrate of video streams

 

Version 3.1.7 - 2011-06-29

Bug fixes (B)

  1. Installer: When upgrading on some PCs the client directory was not created and the player could not be installed
  2. Server: Initialization of high resolution timer was not always done properly

 

Version 3.1.6 - 2011-06-20

Bug fixes (B)

  1. Server: Index file was not correct when upgrading from version < 3.0
  2. Server: In theory it could happen that when a new configuration is set a shutdown notification was not sent to all connected players in live mode

 

Version 3.1.5 - 2011-06-08

Bug fixes (B)

  1. Server/Manager: Login on AXIS camera didn't always work

 

Version 3.1.4 - 2011-05-23

Bug fixes (B)

  1. Server: Username for AXIS camera was not read out of configuration file

 

Version 3.1.3 - 2011-05-09

New features (N)

  1. General: Frame rate decimation is supported on Picolo Ux H264 boards

Bug fixes (B)

  1. Server: When system time was set back then old video data was not overwritten
  2. Installer: ibaCapture-CAM manager shortcut on desktop was not removed during uninstall

 

Version 3.1.2 - 2011-05-04

Bug fixes (B)

  1. Server: If U8 board detected a monochrome video signal then camera would not start
  2. Player: Last frame was not shown when replaying from an mp4 file
  3. Player: Possible crash when restoring a remote desktop session

 

Version 3.1.1 - 2011-04-22

Bug fixes (B)

  1. Server: Disabled cameras caused renumbering of other cameras
  2. Server: It was possible that the server did not try to reconnect to an AXIS camera
  3. Manager: Title text on AXIS cameras was not set correctly
  4. Player: DirectX errors will now change the renderer to GDI mode
  5. Player: the first resize or repaint in ibaAnalyzer sometimes caused an empty or black player
  6. Installer: Service was not always started and firewall exceptions were not always present

 

Version 3.1.0 - 2011-04-11

New features (N)

  1. General: Single installer that includes player, manager and server
  2. General: AXIS IP cameras and video encoders are supported
  3. General: CNB IP cameras are supported
  4. Player: Video can be flipped horizontally and vertically

Improvements (I)

  1. Server: Change in video format (width, height and video compression) doesn't require a rebuild of the index file anymore
  2. Server: Initialization of storage can be resumed after an abort
  3. Manager: When brightness/contrast is not supported then camera view shows this in tooltip
  4. Manager: Camera view is paused when configuration tab is visible and when manager is minimized
  5. Manager: Cameras in camera view don't need to be replaced when upgrading server from version < 3.0 to version 3.1
  6. Player: Brightness and contrast works on more video cards

Bug fixes (B)

  1. Server: Video files were incorrectly removed when there were gaps in the file numbers because of decreased storage size for camera
  2. Manager: Camera name displayed in camera view was not correct after changing the camera name in the configuration

 

Version 3.0.0 - 2011-03-04

New features (N)

  1. Complete rewrite of system
  2. Euresys Picolo Diligent frame grabber supported
  3. Euresys Picolo U8 H.264 frame grabber supported